Under Slab
(use WBBF only)
  1. Place Space Age® white side up.
  2. Place Space Age® flush with walls.
  3. Overlap seams a minimum of 1".
  4. Seal seams with 2" white poly tape.
  5. Install tubing and pour.
Over Radiant Subfloor
(WBBF)
  1. Place Space Age® white side up.
  2. Place Space Age® flush with walls.
  3. Overlap seams 1".
  4. Seal seams with 2" white poly tape.
  5. Install tubing and pour*.
  6. *Concrete must be a minimum of 1½ inches thick.
Under Radiant Subfloor
(use FBBF or WBBF)
  1. Cut Space Age® to run up the wall as high as the finished floor.
  2. Seal joints with 2" foil tape
Between Floor Joist
(use FBBF or WBBF)
  1. Fasten Space Age® between joists.
  2. Staple into place a minimum of 1" below tubing.
Under Floor Joist
(use FBBF or WBBF)
  1. Staple Space Age® to the bottom of joists.
  2. Seal the joints and perimeter with 2" foil tape.